SV652 is an Industrial class & highly-integrated RF transceiver module, which adopts the highperformance Si4432 from Silicon Labs and industrial micro-controller. TTL / 232 /485 can be chosencorresponding to SV652-TTL / SV652-232 / SV652-485. SV652 has good sensitivity and 500mWoutput power to achieve long RF range and reliable RF communication. To avoid the interference,SV652 provides 40 frequency channels and configurable Net ID. SV652 is flexible but easy to use , itcomes with many parameters, such as: frequency, data rate, output power, Net ID, Node ID. Userscan configure the parameters through PC or customer’s own device.
Feature
-
433/470/868/915 MHz (Customizable240-930 MHZ)
-
Industrial class
-
40 channels
-
4 bytes Net ID & 2 bytes Node ID
-
Series Data Rate: 1200 ~ 115200 bps
-
Air Data Rate: 1200 ~ 115200 bps
-
GFSK modulation
-
RSSI
-
Interface: TTL/RS232/ RS485
-
Antenna matching automatically
-
Bi-directional & Half duplex
-
Sensitivity: -121 dBm
-
Max output power: 500 mW (+27 dBm)
-
Working voltage: 3.3~ 6.5V
-
Working temperature: -40 ~ +85 °C
-
Weight: 47g
-
Parameters save automatically
Application
Parameters |
Min. |
Typ. |
Max. |
Unit |
Condition |
Working Condition |
Voltage range |
3.3 |
5.0 |
6.5 |
V |
|
Operating Temperature |
-40 |
25 |
+85 |
℃ |
|
Current Consumption |
Rx current |
|
25 |
|
mA |
TTL level |
|
34 |
|
mA |
485 level |
|
32.7 |
|
mA |
232 level |
Tx current |
|
350 |
|
mA |
@27dBm |
Sleep current |
|
<5 |
|
uA |
@TTL level |
RF Parameters |
Frequency range
|
414.92 |
433.92 |
453.92 |
MHz |
@433MHz |
470.92 |
490.92 |
509.92 |
MHz |
@490MHz |
849.92 |
868.92 |
888.92 |
MHz |
@868MHz |
895.92 |
914.92 |
934.92 |
MHz |
@915MHz |
Data rate |
1.2 |
9.6 |
115.2 |
Kbps |
GFSK |
Output power |
20 |
/ |
+27 |
dBm |
|
Sensitivity |
|
-121 |
|
dBm |
@1.2Kbps |
Typical application:
Pin definition:
Pin No. |
Definition |
Description |
1 |
VCC |
Connected to the positive power supply (typical 5V) |
2 |
GND |
Connected to ground |
3 |
TXD |
TXD of the module and connect to external RXD |
4 |
RXD |
RXD of the module and connect to external TXD |
5 |
SET |
Configuration mode enable (low to enter into the setting mode, leave open or connect high level to exit setting mode) Valid when CS Pin is high or leave open. |
6 |
CS/NC |
For the default version of the module, this pin needs to be left floating (the module has a built-in anti-crash self-reset circuit) Note: Customers can customize the sleep version of the program (without self-reset function), low level sleep, current lower than 5uA, default high level output. |
Mechanical dimension:
Datasheet Download